Our Single Shed Pin Insulator is specifically crafted to provide optimal insulation and mechanical support for overhead electrical lines. With its single shed configuration, it effectively minimizes leakage currents by shedding water and dirt efficiently, ensuring stable operation even in polluted or humid environments.

Aerodynamic Type (AC): Main technical parameters of disc suspension toughened glass insulators (GB and IEC)
 

Insulator

Model

IEC Standard

Insulator

Drawing Number

Nominal

Diameter

D

(mm)

Structure

Height

H(mm)

Nominal

Creepage

Distance

L

(mm)

Connection

Marking

(mm)

Rated

Mechanical

Breakdown
Load

(kN)

Individual

Tensile

Load

Test(

kN)

Power Frequency

Dry Endurance

Withstand Voltage

(kV)

Power Frequency

Wet Endurance

Withstand Voltage

(kV)

Lightning

Impulse

Withstand

Voltage

(kV)

Impulse

Overvoltage

Breakdown Withstand

Voltage

(p.u.)

Minimum Power
Frequency Breakdown

Withstand

Voltage

(kV)

Radio

Interference

10kV

1 MHz (μV)

Visible Electric

Creepage Voltage

Foot/Crown (kV)

Power Frequency Voltage

Arc Test

Insulator

Single Piece Weight

(kg)

LXAP-70U70BP/146M93801463651670355545902.8130≤5018/220.12s/20kA5.3
LXAP-100U100BP/146M938014636516100505545902.8130≤5018/220.12s/20kA5.2
LXAP-120U120BP/146M938014636516120605545902.8130≤5018/220.12s/20kA5.4
LXAP-160U160BP/155M1042015538020160806050952.8130≤5018/220.12s/20kA7.2
LXAP-210U210BP/17OM10420170380202101056050952.8130≤5018/220.12s/20kA7.3
LXAP-240U240BP/170M10420170380242401206050952.8130≤5018/220.12s/20kA7.5

 

Aerodynamic Type (DC): Main technical parameters of disc suspension toughened glass insulators (GB and IEC)

Insulator

Model

IEC Standard

Insulator

Drawing Number

Nominal

Diameter

D

(mm)

Structure

Height

H(mm)

Nominal

Creepage

Distance

L

(mm)

Connection

Marking

(mm)

Rated

Mechanical

Breakdown
Load

(kN)

Individual

Tensile

Load

Test(

kN)

DC

Dry Endurance

Withstand Voltage

(kV)

DC

Wet Endurance

Withstand Voltage

(kV)
 

Lightning

Impulse

Withstand

Voltage

(kV)

Impulse

Overvoltage

Breakdown Withstand

Voltage

(p.u.)

SF6

Breakdown

Withstand Voltage

(kV)
 

Radio

Interference

10kV

1 MHz (μV)

DC

Visible Corona

Voltage Foot/Crown

(kV)
 

Insulator

Single Piece Weight

(kg)

LXAZP-160U160BP/146M104201703902016080140601102.8210≤50≥5010
LXAZP-210U210BP/146M1042017039020210105140601102.8210≤50≥5010.4

Our Single Shed Pin Insulator is specifically crafted to provide optimal insulation and mechanical support for overhead electrical lines. With its single shed configuration, it effectively minimizes leakage currents by shedding water and dirt efficiently, ensuring stable operation even in polluted or humid environments. The robust construction—available in either glazed porcelain or high-grade composite materials—ensures excellent dielectric strength and mechanical load capacity.

The single shed pin insulator is easy to mount on distribution poles and offers a secure grip on the conductor, reducing the risk of electrical faults. Designed for use in distribution voltages up to 33kV, it is highly reliable in both urban and rural utility applications.

Resistant to cracking, aging, and environmental degradation, our single shed pin insulator promises extended service life with minimal maintenance. It is rigorously tested to meet international electrical and mechanical standards, making it a dependable choice for modern power distribution systems.

Key words:

newest single shed pin insulator

Glass insulator

Related News


Customers from several countries visited our factory for inspection.

Today, our company welcomed important clients from many countries to visit and inspect our factory. This is a significant milestone for our company's global reach, and a moment to showcase our strength and achievements. We are deeply honored and are full of confidence for the future.

2025-04-27

What are the characteristics of glass insulators?

After vacuum injection, the continuous pulling and extrusion of epoxy glass pulling rods is formed after the glass fibers are impregnated with epoxy resin and cured. The insulators used in overhead lines commonly include pin insulators, disc insulators, suspension porcelain bottle insulators, porcelain cross arms, rod insulators, and tension insulators, etc.

2024-05-22

In one minute, let you understand glass insulators.

Glass insulators are widely used in power systems due to their excellent electrical performance, corrosion resistance, and mechanical strength. Next, let's take a detailed look at their advantages.

2024-05-22

Get Quote


* Please leave your phone number and we will contact you within 24 hours!