Aerodynamic Type (AC): Main technical parameters of disc suspension toughened glass insulators (GB and IEC)
Insulator Model | IEC Standard Insulator | Drawing Number | Nominal Diameter D (mm) | Structure Height H(mm) | Nominal Creepage Distance L (mm) | Connection Marking (mm) | Rated Mechanical Breakdown (kN) | Individual Tensile Load Test( kN) | Power Frequency Dry Endurance Withstand Voltage (kV) | Power Frequency Wet Endurance Withstand Voltage (kV) | Lightning Impulse Withstand Voltage (kV) | Impulse Overvoltage Breakdown Withstand Voltage (p.u.) | Minimum Power Withstand Voltage (kV) | Radio Interference 10kV 1 MHz (μV) | Visible Electric Creepage Voltage Foot/Crown (kV) | Power Frequency Voltage Arc Test | Insulator Single Piece Weight (kg) |
| LXAP-70 | U70BP/146M | 9 | 380 | 146 | 365 | 16 | 70 | 35 | 55 | 45 | 90 | 2.8 | 130 | ≤50 | 18/22 | 0.12s/20kA | 5.3 |
| LXAP-100 | U100BP/146M | 9 | 380 | 146 | 365 | 16 | 100 | 50 | 55 | 45 | 90 | 2.8 | 130 | ≤50 | 18/22 | 0.12s/20kA | 5.2 |
| LXAP-120 | U120BP/146M | 9 | 380 | 146 | 365 | 16 | 120 | 60 | 55 | 45 | 90 | 2.8 | 130 | ≤50 | 18/22 | 0.12s/20kA | 5.4 |
| LXAP-160 | U160BP/155M | 10 | 420 | 155 | 380 | 20 | 160 | 80 | 60 | 50 | 95 | 2.8 | 130 | ≤50 | 18/22 | 0.12s/20kA | 7.2 |
| LXAP-210 | U210BP/17OM | 10 | 420 | 170 | 380 | 20 | 210 | 105 | 60 | 50 | 95 | 2.8 | 130 | ≤50 | 18/22 | 0.12s/20kA | 7.3 |
| LXAP-240 | U240BP/170M | 10 | 420 | 170 | 380 | 24 | 240 | 120 | 60 | 50 | 95 | 2.8 | 130 | ≤50 | 18/22 | 0.12s/20kA | 7.5 |
Aerodynamic Type (DC): Main technical parameters of disc suspension toughened glass insulators (GB and IEC)
Insulator Model | IEC Standard Insulator | Drawing Number | Nominal Diameter D (mm) | Structure Height H(mm) | Nominal Creepage Distance L (mm) | Connection Marking (mm) | Rated Mechanical Breakdown (kN) | Individual Tensile Load Test( kN) | DC Dry Endurance Withstand Voltage (kV) | DC Wet Endurance Withstand Voltage (kV) | Lightning Impulse Withstand Voltage (kV) | Impulse Overvoltage Breakdown Withstand Voltage (p.u.) | SF6 Breakdown Withstand Voltage (kV) | Radio Interference 10kV 1 MHz (μV) | DC Visible Corona Voltage Foot/Crown (kV) | Insulator Single Piece Weight (kg) |
| LXAZP-160 | U160BP/146M | 10 | 420 | 170 | 390 | 20 | 160 | 80 | 140 | 60 | 110 | 2.8 | 210 | ≤50 | ≥50 | 10 |
| LXAZP-210 | U210BP/146M | 10 | 420 | 170 | 390 | 20 | 210 | 105 | 140 | 60 | 110 | 2.8 | 210 | ≤50 | ≥50 | 10.4 |

Our Single Shed Pin Insulator is specifically crafted to provide optimal insulation and mechanical support for overhead electrical lines. With its single shed configuration, it effectively minimizes leakage currents by shedding water and dirt efficiently, ensuring stable operation even in polluted or humid environments. The robust construction—available in either glazed porcelain or high-grade composite materials—ensures excellent dielectric strength and mechanical load capacity.
The single shed pin insulator is easy to mount on distribution poles and offers a secure grip on the conductor, reducing the risk of electrical faults. Designed for use in distribution voltages up to 33kV, it is highly reliable in both urban and rural utility applications.
Resistant to cracking, aging, and environmental degradation, our single shed pin insulator promises extended service life with minimal maintenance. It is rigorously tested to meet international electrical and mechanical standards, making it a dependable choice for modern power distribution systems.
Key words:
newest single shed pin insulator
Glass insulator
Related News